Perencanaan Titik Hydrant Pada Gudang PT. Putraduta Buanasentosa Menggunakan Standart NFPA 14

Authors

  • Aditio Achmad Fauzi Universitas 17 Agustus 1945 Surabaya
  • Aditya Pradana Universitas 17 Agustus 1945 Surabaya
  • Dwi Novita Indirani Universitas 17 Agustus 1945 Surabaya
  • Wanda Ardhani Sulistyo Universitas 17 Agustus 1945 Surabaya
  • Dika Ayu Safitri Universitas 17 Agustus 1945 Surabaya

DOI:

https://doi.org/10.61132/venus.v2i2.263

Keywords:

Hydrant, Fire, Warehouse, NFPA 14

Abstract

Awareness of potential hazards, risks of accidents, and the need for preventive measures is a must to create a safe and healthy working environment for all workers.  The choice to implement a hydrant system is seen as an effective preventive measure in addressing potential fire risks, which are a major threat to the warehouse environment.  Thus, this research planning has not only a purely academic purpose, but also seeks to make practical contributions to strengthening the application of the Principles of Occupational Safety and Health in the industrial sector.  The planning research was done by jumping directly into the field and the data source was obtained from interviews with local authorities.  This research describes the design of the hydrant system in order to be able and meet the safety standards set by the NPFA. The results of the conservation of the warehouse of PT. Putraduta Buanasentosa then the author was able to describe the building based on the construction of the building. The warehouse PT. Putraduta Buanasentoza requires hydrant boxes of 6 pieces. The water requirements for the fire protection system based on NFPA have been calculated by considering the building size as well as the risk of fire with hydrant 6 pieces and 1 hydrant pillar, requires 4800 liters of water/minute and to extinguish the fire in the event of a fire requires a time of 15 minutes where the required water requirements in 15 minutes is 72.000 litres of water.

References

Anwar, K., Firman, M., & Irfansyah, M. (2020). Perencanaan Sistem Instalasi Hidrant Pada Universitas Islam Kalimantan. Al-Jazari Jurnal Ilmiah Teknik Mesin, 4(2), 81–84. https://doi.org/10.31602/al-jazari.v4i2.2642

Gayle Pennel. (2019). NFPA 20 Installation of Stationary Pumps for Fire Protection. 2019 Edition.

Hartono, Widi. 2017. Sistem Proteksi Kebakaran Gedung.

Kementerian Tenaga Kerja. (1999). Kepmenaker 186/1999 Unit Penanggulangan Kebakaran di Tempat Kerja. Kepmenaker, 186, 1–15

Maulana, R., & Handayani, P. (2022). Gambaran Umum Kesesuaian Sistem Proteksi Aktif Berdasarkan National Fire Protection Association ( NFPA ) di PT Chandra Asri Site Office Cilegon in 2022 Overview of Active Protection System Conformity Based On National Fire Protection Association ( NFPA ) . 1(2), 1–9.

National Fire Protection Association. (2019). NFPA 14. Standard for the Installation of Standpipe and Hose Systems, 2019 Edition.

Rosyidiin, A.F. dkk. (2023). Perencanaan Proteksi Kebakaran Sistem Hydrant Menurut Standard NFPA 14 dan NFPA 20 pada Gedung Cak Durasim UPT. Taman Budaya Jawa Timur. Journal of Information Technology and Computer Science, 6(2). 991 – 997.

Santoso, G., 2004. Manajemen keselamatan dan kesehatan kerja. Prestasi Pustaka Publisher.

Stephen M. Leyton. (2019). NFPA 14 Standard for the Installation of Standpipe and Hose Systems. 2019 Edition.

Yuniarto, H., & Bhiwara, W. . (2017). Perancangan Jalur Hidran Pada Gudang Persediaan Materiil BEKMATPUS LANUD Halim Perdanakusuma. Teknik Industri, 6(2), 75–91. https://journal.universitassuryadarma.ac.id/index.php/jtin/article/download/221/198

Downloads

Published

2024-04-19

How to Cite

Aditio Achmad Fauzi, Aditya Pradana, Dwi Novita Indirani, Wanda Ardhani Sulistyo, & Dika Ayu Safitri. (2024). Perencanaan Titik Hydrant Pada Gudang PT. Putraduta Buanasentosa Menggunakan Standart NFPA 14. Venus: Jurnal Publikasi Rumpun Ilmu Teknik , 2(2), 144–149. https://doi.org/10.61132/venus.v2i2.263