Analisis Penyeimbangan Beban Secara Manual Menggunakan Metode Dua Titik Waktu pada Transformator Distribusi 50 kVA PNIAI007

Authors

  • Rangga Bismantara Universitas Islam Sultan Agung
  • Arief Marwanto Universitas Islam Sultan Agung

DOI:

https://doi.org/10.61132/jupiter.v4i3.1376

Keywords:

load imbalance, neutral current, power loss, load balancing, two-time-point method

Abstract

Load imbalance in three-phase distribution transformers can increase neutral current and power losses, thereby reducing the efficiency and reliability of electric power distribution systems. This study aims to analyze the level of load imbalance, power losses caused by neutral current, and the effectiveness of manual load balancing using the two-time-point method, namely peak load time (PLT) and off-peak load time (OPLT). The research was conducted on the PNIAI007 distribution transformer at PT PLN (Persero) ULP Enarotali using a quantitative descriptive approach with a case study design. Data were obtained through measurements of phase currents and neutral current, which were then analyzed to compare conditions before and after load balancing.The results show that the load imbalance level was significantly reduced from more than 29% to 2.47% during daytime operation and 1.21% during nighttime operation. The neutral current decreased from 37.81 A to 14.58 A during the daytime and from 51.76 A to 19.83 A at night. In addition, power losses due to neutral current were reduced by more than 85%. These results indicate that the two-time-point load balancing method is effective in improving the efficiency and operational reliability of distribution transformers.

References

Azis, A., Rizal, M., Emidiana, E., Pebrianti, I. K., Amin, M. S. Al, Nurdiana, N., Perawati, P., & Irwansi, Y. (2024). Analysis of load imbalance in Tarakan distribution transformer of PT PLN (Persero) Sukarami customer service unit. Maǧallaẗ Al-Handasaẗ Wa-al-Tiknūlūǧiyā. https://doi.org/10.47191/etj/v9i05.12

dos Santos, Q. F., Soares, J. G., & Siband, R. L. (2025). Calculation and analysis of balanced loads in 20 kV distribution system. Syntax Literate: Jurnal Ilmiah Indonesia. https://doi.org/10.36418/syntax-literate.v10i10.62223

Hafizh, Mhd. R. Al. (2025). Studi pengaruh beban tak seimbang pada transformator distribusi Gardu SL.247 di PT PLN (Persero) ULP Sunggal. Jurnal Teknologi Rekayasa Instalasi Listrik. https://doi.org/10.51510/jtril.v1i1.1725

Hidayat, R., Pratama, A., & Yusuf, M. (2022). Evaluasi sistem distribusi tenaga listrik untuk meningkatkan keandalan jaringan. Jurnal Energi dan Kelistrikan, 10(2), 88–95.

Iman, D. F., Khaerunnisa, P., Fitri, H. M., & Aribowo, D. (2024). Analisis operasional sistem distribusi tegangan menengah ke tegangan rendah di Gardu Induk Serang. Journal of Electrical Power Control and Automation, 7(2), 66–71. https://doi.org/10.33087/jepca.v7i2.119

Mulyadi, A. D. (2011). Pengaruh ketidakseimbangan beban pada rugi daya saluran netral jaringan distribusi tegangan rendah. Jurnal Teknik Energi.

Pranoto, S., Sofyan, & Rusli, N. N. (2020). Penyeimbangan beban pada trafo distribusi penyulang Akkarena di Unit Layanan Pelanggan Mattoanging PT PLN (Persero). Jurnal Teknik Elektro.

Prasetya, I. W. Y., Setiawan, I. N., & Arjana, I. G. D. (2020). Analisis ketidakseimbangan beban dan harmonisa pada transformator distribusi MI 0096 penyulang Abianbase. Jurnal SPEKTRUM, 7(1), 109–115. https://doi.org/10.24843/SPEKTRUM.2020.v07.i01.p16

Prasetyo, D., & Nugroho, A. (2023). Analisis pembebanan transformator distribusi pada jaringan tegangan rendah. Jurnal Teknik Elektro Indonesia, 11(1), 54–61.

PT PLN (Persero). (2014). Metode pemeliharaan trafo distribusi berbasis kaidah manajemen aset. https://id.scribd.com/document/348641264/1-SE-HAR-TRAFO-DIS-0017-E-tahun-2014-pdf

Ramadhan, F., Putri, N., & Saputra, H. (2021). Pengaruh ketidakseimbangan beban terhadap arus netral transformator distribusi. Jurnal Energi Listrik, 9(3), 73–80.

Sampe, A. (2022). Analisis rugi-rugi daya akibat ketidakseimbangan beban pada transformator distribusi 20 kV/380 V di penyulang DPR Kota. Jurnal Sains dan Teknologi, 1(2), 106–123. https://doi.org/10.58169/saintek.v1i2.84

Santos, P., Almeida, R., & Ferreira, J. (2025). Load balancing analysis in low-voltage distribution transformers. International Journal of Electrical Power Systems, 18(2), 55–63.

Savina, N. V., Myasoedov, Y. V., & Myasoedova, L. A. (2018). Influence of quality of the electric energy on reliability of electrical supply systems. 2018 International Multi-Conference on Industrial Engineering and Modern Technologies (FarEastCon), 1–5. https://doi.org/10.1109/FarEastCon.2018.8602690

Setiawan, D., Wijaya, H., & Firmansyah, R. (2021). Penerapan metode penyeimbangan beban berbasis dua titik waktu pada transformator distribusi. Jurnal Teknologi Kelistrikan, 8(4), 115–122.

Sutikno. (2018). Analisis ketidakseimbangan beban transformator distribusi 20 kV dan solusinya pada jaringan tegangan rendah. Jurnal Teknik Elektro, 8(1), 1–7. https://ejournal.unesa.ac.id/index.php/JTE/article/view/26308

Syamsiana, I. N., Prasetyo, B. E., Hassidiqi, H., & Firdaus, S. F. (2023). Balancing load outgoing transformator 2 di Politeknik Negeri Malang. Elposys: Jurnal Sistem Kelistrikan, 10(3), 201–207. https://doi.org/10.33795/elposys.v10i3.4266

Widagdo, R. S., & Andriawan, A. H. (2023). Analysis of losses due to load unbalance in a 2000 kVA transformer at Supermall Mansion 2 Tower Tanglin Surabaya. Journal of Engineering and Science Research. https://doi.org/10.23960/jesr.v5i2.144

Yusmartato, Nasution, R., & Armansyah, A. (2019). Pemilihan fuse cut out untuk pengaman transformator distribusi 400 KVA. JET (Journal of Electrical Technology), 4(2), 73–79.

Zulkhulaifah, P., & Rudito, H. (2021). Analisis pengaruh ketidakseimbangan beban trafo distribusi 20 kV terhadap rugi-rugi daya dan efisiensi pada penyulang Hertasning Baru PT PLN (Persero) ULP Panakukkang Makassar. Seminar Nasional Teknik Elektro dan Informatika, 6–11.

Downloads

Published

2016-05-25

How to Cite

Rangga Bismantara, & Arief Marwanto. (2016). Analisis Penyeimbangan Beban Secara Manual Menggunakan Metode Dua Titik Waktu pada Transformator Distribusi 50 kVA PNIAI007. Jupiter: Publikasi Ilmu Keteknikan Industri, Teknik Elektro Dan Informatika, 4(3), 19–33. https://doi.org/10.61132/jupiter.v4i3.1376