Abstract

Electrical power is a very important source for life. One of the electrical components is a distribution transformer which is used to transmit electrical voltage from the substation to the load center. Every year the electricity demand increases, so that the transformer works optimally, you must also pay attention to the loading. Load imbalance on electric power distribution transformers always occurs and this imbalance occurs due to the use of electrical energy. The current flowing in the neutral conductor of the transformer causes an imbalance in the transformer load and losses, namely losses due to the neutral current in the neutral conductor of the transformer. When analyzing mass, use quantitative methods. After analysis, it shows that the transformer is in an unbalanced state where neutral current appears in the transformer. To determine the efficiency of the distribution transformer

 

References

I Wayan Suldiartha, I Pultul Sultawinaya, I keltult TA and Ardy Firman " MANAJElMElN TRAFO DISTRIBUlSI 20KV ANTAR GARDUl BL031 DAN BL 033 PElNYUlLANG LILIGUlNDI DElNGAN MElNGGUlNAKAN SIMUlLASI PROGRAM ElTAP, vol. 16, no. 3, pp. 166-171, 2016.

I Pultul Sultawinaya, A.A.N.M. Narottama, dan I.G.N. Adel Puljana, Melningkatkan kinelrja gardul distribulsi SK76 Pelnyullang Sulkasada dalam melnangani ovelrblast melnggulnakan simullasi pelrangkat lulnak ElTAP, vol.3, pp. 1-7, 2022

Samsulrizal, & Hadinoto, B. 2020. Stuldi Analisis Dampak Ovelrload Transformator telrhadap Kulalitas Daya di PT.PLN (Pelrselro) UlP3 Pondok Geldel, Kilat, 136-142

Elddy Warman, "Pelmilihan Dan Pelningkatan Pelnggulnaan / Pelmakaian Selrta Manajelmeln Trafo Distribulsi", Meldan: Ulnivelrsitas Sulmatelra Ultara, 2004.

Kadelk, Wahyuldi, Widiatmika. 2018 Analisis Pelnambahan Tranformator Sisipan Ulntulk Melngatasi Ovelrload Pada Transformator DB0244 Di Pelnyullang Selbellangga