Efisiensi Penggunaan Dosis Optimum Poly Aluminium Chloride (PAC) Terhadap Volume Lumpur yang Terkandung dalam Satu Liter Air Baku

Authors

  • Putri Cahyaning Sri Hartini UPN ”Veteran” Jawa Timur
  • Munawar Ali UPN ”Veteran” Jawa Timur

DOI:

https://doi.org/10.61132/venus.v2i4.388

Keywords:

Optimum Dosage, Jartest, PAC, Poly Aluminium Chloride, Sludge Volume

Abstract

Sludge is a by-product of an activity that comes from the discharge outlet of the flocculation, sedimentation and backwash filtration basins. To determine the volume of sludge contained in one liter of raw water, it is necessary to conduct a Jartest Test by determining the optimum dose of PAC. This water sampling was carried out at the Krian 1 Water Treatment Plant (IPA). Primary data collection is obtained from Imhoff Cone Results data. While for secondary data collection we get from Jartest data.  The manufacture of the coagulant solution used is Poly Aluminum Chloride (PAC). The average turbidity value in February was around 123 NTU and there was an increase in turbidity on the seventh day which reached 237 NTU. The drastic increase in turbidity reached 455 NTU with an average turbidity in March of 130 NTU. The graph shows that there is a significant correlation between the volume of sludge produced during the treatment process and the level of water turbidity. Thus, the researcher suggests further treatment of the remaining sludge which can be done by making a Sludge Drying Bed (SDB).

 

References

Effendi, H. 2003. Telaah Kualitas Air Bagi Pengelolaan Sumber Daya dan Lingkungan Perairan. Yogyakarta: Penerbit Kanisius.

Khafila, R. (2013). OPTIMASI KOAGULAN PADA PROSES KOAGULASI-FLOKULASI PENGOLAHAN AIR BERSIH DI PDAM UNIT TEGAL GEDE.

Linggawati, A. 2006. Efektivitas Pati-Fosfat dan Koagulan. Jurnal Natur Indonesia

Masduqi, A., & Assomadi, A. F. (2012). Operasi dan proses pengolahan air. Jurusan Teknik Lingkungan Institute Teknologi Sepuluh Nopember. Surabaya.

Oktaviasari, S. A., Mashuri, M., & Statistika, J. (2016). Optimasi Parameter Proses Jar Test Menggunakan Metode Taguchi dengan Pendekatan PCR-TOPSIS (Studi Kasus: PDAM Surya Sembada Kota Surabaya) (Vol. 5, Issue 2).

Peraturan Menteri Kesehatan Republik Indonesia. (2023). BERITA NEGARA REPUBLIK INDONESIA (PERMENKES NOMOR 2 TAHUN 2023). www.peraturan.go.id

Raharja, S., Utari, M., & Hartanto, S. (2015). Pengaruh Tekanan Pompa Sludge dan Laju Alir Flokulan Terhadap Kadar Air Akhir Sludge di Dalam Mesin Beltpress (Effect of Sludge Pressure Pump and Flocculants Flow Rate to Final Water Content Against Cake in Beltpress Machine).

Ramadhani, S., Tunggul Sutanhaji, A., Bambang Rahadi Widiatmono, dan, Kunci, K., Biji Kelor, T., & Sungai, A. (2013). Perbandingan Efektivitas Tepung Biji Kelor (Moringa oleifera Lamk), Poly Aluminium Chloride (PAC), dan Tawas sebagai Koagulan untuk Air Jernih Effectiveness Comparison of Moringa Seed Flour (Moringa oleifera lamk), Poly Aluminium Chloride (PAC), and Alum as Coagulant for Clear Water. In Jurnal Keteknikan Pertanian Tropis dan Biosistem (Vol. 1, Issue 3).

Published

2024-06-22

How to Cite

Putri Cahyaning Sri Hartini, & Munawar Ali. (2024). Efisiensi Penggunaan Dosis Optimum Poly Aluminium Chloride (PAC) Terhadap Volume Lumpur yang Terkandung dalam Satu Liter Air Baku. Venus: Jurnal Publikasi Rumpun Ilmu Teknik , 2(4), 49–57. https://doi.org/10.61132/venus.v2i4.388

Similar Articles

You may also start an advanced similarity search for this article.