Analisis Hasil Pemantauan Kualitas Air Buangan Setelah Diolah di Unit Waste Water Treatment Komunal PT. X.

Authors

  • Arif Bimo Wicaksono Universitas Pembangunan Nasional “Veteran” Jawa Timur
  • Rizka Novembrianto Universitas Pembangunan Nasional “Veteran” Jawa Timur

DOI:

https://doi.org/10.61132/venus.v3i1.726

Keywords:

Fertilizer, Gresik, Utilization, Waste, Waste Water

Abstract

PT X, one of the state-owned enterprises to support the country's food security, is the largest and most comprehensive fertilizer producer in Indonesia that generates various wastes, including industrial liquid waste. Liquid waste has no economic value, so it is very important to treat it. PT X Company uses potential Hydrogen (pH)ysical and chemical treatment. There are two effluent treatment units, setting, line injection, and sludge treatment. All parameters evaluated include chemical requirements for oxygen (COD), zat padat yang tersuspensi(TSS), ammonia (NH3), total kjehdal nitrogen (TKN), fluorine, degree of acidity (potential of hydrogen (pH)), oil, and fat. According to the results after the analysis conducted in the study, it was found that the air pollution data after wastewater treatment was carried out showed that the quality of wastewater every month had met the quality standards of the rules and could be discharged into water bodies / seas. This shows the effectiveness of the treatment process implemented by the company.

References

Abd-Elshafy, D., Raslan, H., Nadeem, R., Awad, M., Shalaby, S., & Bahgat, M. (2022). Multiple infections with hepatitis A virus and development of rheumatoid arthritis among wastewater treatment plant workers. The Journal of Infection in Developing Countries, 16(1), 187–195.

Karangan, J., Sugeng, B., & Sulardi, S. (2019). Uji keasaman air dengan alat sensor potential hydrogen (pH) di STT MIGAS Balikpapan. Jurnal Kacapuri: Jurnal Keilmuan Teknik Sipil, 2(1), 65.

Lumaela, A. K., Otok, B. W., & Sutikno. (2013). Pemodelan kebutuhan oksigen yang dibutuhkan zat kimia (COD) Sungai di Surabaya dengan metode mixed geographically weighted regression. Jurnal Sains dan Seni Pomits, 2(1), D100–D105.

Miarti, A. (2023). Determination of optimum dose of mixing wastewater WWTP (wastewater treatment plant) with hot water production Lematang River as of parameters potential hydrogen (pH), conductivity, turbidity, and silica use coagulant PAC in PT.X. Jurnal Cakrawala Ilmiah, 2(7), 3087–3098.

Putri, W., Purwiyanto, A., Fauziyah, F., Agustriani, F., & Suteja, Y. (2019). Kondisi nitrat, nitrit, amonia, fosfat, dan BOD di muara Sungai Banyuasin, Sumatera Selatan. Jurnal Ilmu dan Teknologi Kelautan Tropis, 11(1), 65–74.

Rabbi, M., Hossen, J., Sarwar, M., Roy, P., Shaheed, S., & Hasan, M. (2018). Investigation of wastewater quality parameters discharged from textile manufacturing industries of Bangladesh. Current World Environment, 13(2), 206–214.

Rahayu, S., & Purwanto, P. (2018). Integration of cleaner production and wastewater treatment on tofu small industry for biogas production using ANSBR reactor. E3S Web of Conferences, 31, 03010.

Rahman, M. (2022). Evaluasi efektivitas pengolahan air limbah pada instalasi pengolahan air limbah klinik kecantikan. Jurnal Ilmu Lingkungan, 20(4), 841–849.

Susanthi, D., Purwanto, M., & Suprihatin, S. (2018). Evaluasi pengolahan air limbah domestik dengan IPAL komunal di Kota Bogor. Jurnal Teknologi Lingkungan, 19(2), 229.

Yudistira, D. (2022). Analisis kualitas air limbah kilang sebelum dibuang ke badan air. Majalah Ilmiah Swara Patra, 12(1).

Downloads

Published

2025-01-21

How to Cite

Arif Bimo Wicaksono, & Rizka Novembrianto. (2025). Analisis Hasil Pemantauan Kualitas Air Buangan Setelah Diolah di Unit Waste Water Treatment Komunal PT. X. Venus: Jurnal Publikasi Rumpun Ilmu Teknik , 3(1), 146–155. https://doi.org/10.61132/venus.v3i1.726